GMDSS Battery Capacity Test Calculator

·

GMDSS Reserve Battery Calculator & Capacity Test

SOLAS IV/13 • COMSAR/Circ.32

GMDSS Reserve Source of Energy (Battery) Capacity Calculator & Statutory Survey Report Generator

Saved

1. Ship Particulars & Reserve Battery Bank Specifications

Ship Particulars & GMDSS Reserve Battery Bank Technical Specifications

Ship Particulars & Survey Information (SOLAS Survey Record)
Reserve Battery Bank Technical Specifications
-- Specify commissioning date to evaluate age

2. Connected GMDSS Equipment Audit & IMO COMSAR/Circ.32 Current

SOLAS IV/13.2 Autonomy Requirement & Equivalent Discharge Current Formula

Statutory Autonomy Requirement (SOLAS IV/13.2):
Active Connected GMDSS Radio Equipment Rx Current (A) Tx Current (A) Continuous / Other (A) Circ.32 Equivalent (A)
Sub-totals: 0.00 A 0.00 A 0.00 A 0.00 A
IMO COMSAR/Circ.32 Discharge Current Formula:
Itotal = Σ Irx + 0.5 × Σ Itx + Σ Iother
Itotal = 0.0 + (0.5 × 0.0) + 0.0 = 0.00 A
Equivalent Discharge Current (Itotal) 0.00 A Equivalent continuous discharge rate
Required Capacity (Crequired) 0.00 Ah Based on 1 Hour duty
Design Reserve Margin (Margin) 0.00x Compliant

3. Periodic Discharge Measurements Log & Vector Curve

Periodic Discharge Measurements & Interactive Vector Discharge Curve

Step Time (min) Total V (V) Current (A) Batt #1 V (V) Batt #2 V (V) ΔV (V) Temp (°C)
Vector Discharge Profile (Terminal Voltage Under Load)
Actual Bank Voltage SOLAS Cut-off Limit: 21.6 V (1.80 V/cell) Degradation Zone (< 21.6 V)

4. Degradation Analysis & Statutory Compliance Verdict

Numerical Capacity Integration (Trapezoidal Rule), SOH Assessment & Statutory Verdict

Actual Delivered Capacity (Cactual) 0.00 Ah Integrated via Trapezoidal Rule
End-of-Discharge Voltage (End V) 0.00 V SOLAS threshold ≥ 21.60 V
Max Monoblock Imbalance (ΔVmax) 0.00 V Permissible delta ≤ 0.30 V
State of Health (SOH) 0.0 % Minimum statutory ≥ 80.0%
SOLAS Chapter IV Reg. 13 & IMO COMSAR/Circ.32 Compliance Checklist:
✓
End-of-Discharge Terminal Voltage ≥ 21.60 V (1.80 V/cell) --
✓
State of Health (SOH) ≥ 80.0% of Required Duty --
✓
Monoblock Voltage Symmetry ΔV ≤ 0.30 V --
GMDSS Radio Survey Hub SOLAS // CH.IV REG.13

GMDSS Reserve Source of Energy Capacity Testing: SOLAS IV/13 & IMO COMSAR/Circ.32

The annual verification of the GMDSS Reserve Source of Energy is a critical statutory checkpoint during annual Safety Radio Surveys by classification societies (DNV, LR, BV, ABS, ClassNK) and Port State Control (PSC) inspections. Governed by SOLAS Chapter IV Regulation 13, IMO Resolutions A.694(17), A.702(17), and circular IMO COMSAR/Circ.32, radio batteries must demonstrate verified operational endurance under distress duty conditions.

The GMDSS Reserve Battery Calculator & Capacity Test Pro automates connected load audits, determines statutory 1-hour or 6-hour minimum capacity demands, logs periodic discharge readings (via load bank or live equipment load), performs trapezoidal capacity integration, tracks monoblock symmetry, and renders an interactive discharge profile. An integrated print isolation engine formats an official A4 compliance certificate with zero advertising interference.

IMO Load Auditing
COMSAR/Circ.32 Current
Automated distress duty cycle computation via formula Itotal = Irx + 0.5·Itx + Iother mapped against 1-hour or 6-hour SOLAS autonomy criteria.
Degradation Analysis
Trapezoidal Integration & SOH
Numerical Ah integration across elapsed test intervals, State of Health (SOH) evaluation, monoblock ΔV symmetry verification, and end-voltage monitoring.
Statutory Reporting
Official Survey Certificate
High-resolution vector SVG discharge profile, statutory Pass/Fail verdict seal, and extreme DOM isolation for clean A4 PDF survey record printing.

Frequently Asked Questions (GMDSS Battery Survey FAQ)

When is a vessel required to maintain 1 hour vs. 6 hours of GMDSS battery reserve?
Under SOLAS Chapter IV Regulation 13.2, a 1-hour reserve duration is permitted if the vessel is equipped with an emergency generator that fully complies with SOLAS Chapter II-1 Regulations 42 or 43 (automatic starting and automatic transfer to power the GMDSS console upon main power failure). If the vessel is not fitted with an emergency generator, or if the generator is not configured to supply the GMDSS console, the reserve battery bank must provide at least 6 hours of continuous autonomous radio operation.
What terminal voltage indicates a battery failure during the discharge test?
For a standard 24-volt lead-acid installation (AGM or GEL VRLA), the statutory cut-off voltage is 21.60 V DC (1.80 V per 2V cell). If the terminal voltage drops below 21.60 V under load before the required 1-hour or 6-hour period elapses, the battery fails the survey and must be replaced prior to departure.
Why is the monoblock voltage imbalance limit set to 0.30 V?
In a 24V series bank (e.g., two 12V monoblocks), a voltage disparity (ΔV = |V1 - V2|) exceeding 0.30 V points to severe cell degradation, internal short circuits, or heavy sulfation in one block. Even if the combined bank voltage temporarily measures above 21.60 V, the weaker monoblock will suffer polarity reversal under emergency loads, posing an immediate risk of radio console blackout.
What is the recommended service life for GMDSS reserve batteries?
Most classification societies and marine battery manufacturers recommend replacing VRLA (AGM/GEL) batteries every 3 to 5 years. Under IMO COMSAR/Circ.32, batteries exceeding 36 months (3 years) in service warrant heightened inspection, and ships' officers should perform internal discharge checks quarterly to detect accelerated capacity fade.
Can survey results be saved and exported for company records?
Yes. All vessel particulars, equipment load currents, and periodic discharge readings auto-save to browser LocalStorage. The "Export JSON" button generates an archival file for company safety records, while "Print Protocol (PDF)" renders a vector-accurate, ad-free A4 survey report ready for surveyor and Master signatures.
Regulations: SOLAS IV/13, IMO Res. A.694(17), A.702(17)
Test Method: IMO COMSAR/Circ.32 (Discharge Test & SOH ≥ 80%)
Survey: Annual Safety Radio Survey & PSC Ready